Class DataSourceRouterOptions
- Namespace
- ReportWright.Data
- Assembly
- ReportWright.Data.Abstractions.dll
What the router enforces on every query, whatever the provider does.
public sealed class DataSourceRouterOptions
- Inheritance
-
DataSourceRouterOptions
- Inherited Members
Constructors
- DataSourceRouterOptions()
Initializes the options with the defaults.
Properties
- DefaultTimeout
Gets or sets the timeout for a dataset whose query states none (or states zero, RDL's "no limit"). Default 30 seconds; null for none.
- MaxRows
Gets or sets the row cap a query fails at, on top of the engine's own dataset limit. Default one million; null for none. A cap is a refusal, never a truncation.
- MaxTimeout
Gets or sets the ceiling a dataset's own
Timeoutcannot exceed: a report is untrusted input and may ask for a year. Default 10 minutes; null for none.
Methods
- For(int?)